Utility of Surgeon-Performed Ultrasound in an Otorhinolaryngology-Head and Neck Surgery Residency Training Program: A Single Institution Analysis

Authors

Keywords:

ultrasound, fine needle biopsy, core needle biopsy, head and neck procedures, ORL-HNS, residency training

Abstract

Objective: This two-part study aims to describe our experience in surgeon-performed ultrasound-guided procedures, particularly Fine Needle Biopsy (FNB) and Core Needle Biopsy (CNB) in the ORL-HNS residency training program at the University of Santo Tomas Hospital, and to evaluate procedural outcomes, specifically specimen adequacy as well as secondary diagnostic performance of cytological yields among patients with available surgical histopathology.

Methods:
Design: Cross-sectional Survey
Setting: Retrospective Review of Records
Participants: Tertiary Private University Training Hospital 16 ORL-HNS physicians (10 residents, 6 alumni) 246 biopsy results

Results: In Part 1, of 16 ORL-HNS physicians (10 residents, 6 alumni) surveyed, trainees reported a mean confidence of 4.06 ± 0.93 in operating ultrasound equipment, with 13 (81.25%) having attended relevant training courses. Ninety percent (90%) of residents planned to incorporate surgeon-performed ultrasound in practice, while 100% of alumni reported active clinical utilization. In Part 2 (N = 246 biopsies), overall specimen adequacy was 89.02% (n = 219). Specimen adequacy rates showed no statistically significant difference across residency year levels and alumni (ranging from 83.64% to 95.00%, χ2=4.08, p=.421). Overall cytology yielded 64.23% (n = 158) benign, 24.80% (n = 61) atypical/suspicious/malignant, and 10.98% (n = 27) non-diagnostic (Bethesda I / paucicellular / cyst fluid only) specimens. As a secondary exploratory analysis, cytological results compared against final histopathology in the subset of 53 surgically treated patients, demonstrated a sensitivity of 79.40%, specificity of 57.90%, and an AUC-ROC of 0.69 (95% CI: 0.55–0.82) for cytological diagnosis.

Conclusion: This overview of our institutional experience with surgeon-performed ultrasound demonstrates high trainee engagement, confidence in basic applications, and strong long-term utilization among alumni (Part 1) and confirms favorable procedural outcomes, with an overall specimen adequacy rate of 89.02% across all training levels (Part 2). While residency year level served as a surrogate for training level, specimen adequacy remained consistently high across cohorts. Future prospective studies tracking individual procedure logs and long-term diagnostic performance are recommended to directly evaluate skill acquisition over time.

Downloads

Download data is not yet available.

Downloads

Published

2026-11-15

How to Cite

1.
Ampoloquio D, Capuz MK. Utility of Surgeon-Performed Ultrasound in an Otorhinolaryngology-Head and Neck Surgery Residency Training Program: A Single Institution Analysis. Philipp J Otolaryngol Head Neck Surg [Internet]. 2026 Nov. 15 [cited 2026 Nov. 16];41(2):40. Available from: https://pjohns.pso-hns.org/index.php/pjohns/article/view/2457